TideGateway

Hull-03A

Hull, Straits Pond

42.260352, -70.844748

Technical Specifications

Basic Properties

Type
Tide Gate
Material
Metal
Control
Electric Actuator
Condition
Geometry
Rectangular
Status
Active
Number of Gates
2

Operator & Management

Operator Type
PUBLIC
Operator
Towns of Hull, Hingham, and Cohasset
Permits
WQC, ACOE
Purpose
Flood Protection and Restoration

Dimensions & Elevations

Dimensions
5ft diameter, 7ft height
Invert Elevation
Installation Date
2010
Tidal Influence

Culvert Details

Restriction Type
Roadway
Geometry
Rectangular
Material
Granite Block
Bottom Material
Number of Pipes
2
Dimensions
12ft diameter, 5ft height
Condition
Good
Comments

Restoration Potential

Restoration prioritization and planning information from MassBays regional coordination

Assessment

Salt Marsh Impairment due to Tidal Restriction
Moderate
Potential Extent of Marsh Restoration
Moderate
Implementation Feasibility
High
Restoration Priority
High
Recommended Improvement Type
O&M and Infrastructure

Notes

Site shows moderate salt marsh impairment due to restricted tidal flow. Replacement with self-regulating tide gate could restore approximately 5-8 acres of degraded marsh habitat. Good access for construction equipment. Regional coordination completed with town DPW and conservation commission.

Historical Records

Legacy data from previous surveys and documentation

Environmental Data

Invasive Species
Restoration Status
Invasive Comments
Restoration Comments
Upstream Area
Salt Marsh: 94

Notes & Comments

General Comments
Operation Plan
Yes
Operation Comments
O&M Plan overseen by TAC.
Gate Comments
(2) 5'7x7' tide gates replaced in 2010, automated, 3.8 NGVD29 max elevation
Elevation Comments
Visit Comments
Other Comments
External Data Comments
MA DEP Water Quality Cert #W133268 3.4.2008 US ACOE Permit NAE-2005-02204 5.6.2008 Final Straits Pond Tide Gate Operation and Maintenance Plan 12.5.2007 Straits Pond Real Time Monitoring Link https://www.hobolink.com/p/f211da46192a963a9c371d86ea6e7c6e Revised Straits Pond 2012 Monitoring Summary Three (3) engineering design sheets located in "other" folder
© 2026 Massachusetts Bays Program. Monitoring tidegates across Massachusetts.