- General Comments
- Site is located off of Route 1 to the northeast of the Showcase cinemas.
- Operation Comments
- Three SRTs are installed at this location and are not being operated per permit conditions. Refer to noncompliance document uploaded to the SharePoint website.
- Gate Comments
- There are three (3) metal self regulating tide gates (SRTs) installed at the site and an additional eight (8) conventional metal flap gates. The SRTs are located at the southernmost end of the headwall. The conventional metal flap gates are present for flood protection while the SRTs are installed to provide flood protection and restoration. Based on plans and photos it appears that the dimensions of the 3 SRT's are approximately 6' by 6'. Dimensions of the flap gates are unknown, but also appear to be on the order of 6' by 6'. As of 11/4/2015, the central SRT (Revere-08B) was missing the bottom float and not operational. Tidal leakage was also observed at and around the conventional flap gates.
- Elevation Comments
- Invert elevation of SRTs is 1.95 Boston City Base (BCB) Datum. High water elevation is 10.69 BCB.
- Other Comments
- Upstream affected area is approximate.
- External Data Comments
- US ACOE CENAE-R-1997-00838 Permit 11.3.1999
US ACOE Permit 1997-00838 & MA DEP Permit 61-294 Non-Compliance Document (Other)